What is an emission factor? How is activity data converted to carbon equivalent?

What is an emission factor and how is it used? How activity data becomes CO2e, the electricity factor, sources of factor tables and what to keep in the record.

FUFerhat UğurluYazSis TeamPublished: November 28, 20268 min read
In short

An emission factor is the coefficient that gives how much greenhouse gas one unit of an activity (a litre of fuel, a kilowatt-hour of electricity) produces, as carbon dioxide equivalent. The calculation is simple: emissions equal activity data times emission factor. The hard part is choosing a factor with the right unit and a known source, and recording it with its version.

You have an electricity bill, and consumption on it is written in kilowatt-hours. The sustainability report, however, asks for tonnes of carbon dioxide equivalent, that is, CO2e. The fuel bill shows litres, the logistics report tonne-kilometres, the purchasing record kilograms. None of these is carbon directly; each is a measure of an activity. The coefficient that does the conversion in between is called the emission factor, and almost every figure in a carbon calculation passes through a factor. If you choose the factor wrong, the result is wrong even if the multiplication is right.

An emission factor is the coefficient that gives the amount of greenhouse gas produced by one unit of an activity (such as burning a litre of fuel, consuming a kilowatt-hour of electricity or transporting for one tonne-kilometre) in terms of carbon dioxide equivalent. Below we explain how the factor is used, where it comes from and what information should be kept with it in the record.

How is an emission factor calculated? How is activity data converted to carbon equivalent?

In a corporate carbon calculation you mostly do not calculate the factor; you take it from a published source. What you calculate is the emission, and the formula is just a multiplication:

Emissions (kg CO2e) = Activity data × Emission factor (kg CO2e / activity unit)
  1. Collect the activity data. Take the quantity measured from the invoice, meter or shipment record (for example litres or kilowatt-hours).
  2. Choose the right factor. Find the factor that fits the type of activity, the geography and the period; the factor’s unit must match the unit of the activity data.
  3. Multiply. The result comes out in kg or tonnes of CO2e.
  4. Record it. Write the factor you used, its source and its version next to the result.

A small fictional example: suppose a facility burns 1,000 units of a fictional fuel a year and the published factor for this fuel is 3 kg CO2e per unit. The emission is 1,000 × 3 = 3,000 kg, that is 3 tonnes of CO2e. The numbers here are made up only to show the logic of the calculation; they do not represent a real fuel or factor value.

Which activity is multiplied by which unit?

The most frequent source of error is a unit mismatch: multiplying data in litres by a kilogram-based factor, or mistaking megawatt-hours for kilowatt-hours. The table below illustrates which unit each activity arrives in and which unit it must be multiplied by; the values are deliberately not written.

ActivityUnit of activity dataUnit of the factorResult
Fuel combustion (vehicle, boiler, generator)litres or m³kg CO2e / litre or kg CO2e / m³kg CO2e
Purchased electricitykWhkg CO2e / kWhkg CO2e
Road or sea transporttonne-kmkg CO2e / tonne-kmkg CO2e
Purchased materialskg or tonneskg CO2e / kgkg CO2e
Business travelpassenger-kmkg CO2e / passenger-kmkg CO2e

What is the 2025 electricity emission factor? What should you look at?

There is no single number for the electricity factor and we do not write a figure in this article, because the factor changes with the country’s electricity generation mix and with the year, and the institution that publishes it may announce a new value each period. Take the value you will use from the current publication of the official body that publishes the relevant year, and record its source. Pay attention to two things:

  • Method: Electricity emissions can be calculated with two approaches. The location-based method uses the average grid factor of the region; the market-based method reflects your purchasing choices, such as contracts and certificates. Which one you use must be stated clearly.
  • Year: If the factor for your calculation year has not been published yet, the previous year’s factor may be used; in that case write the year used and the reason in the record. When the year is updated, do not silently change past calculations.

Where do you find an emission factor table, and which source suits when?

Source typeWhen it suitsWhat to watch
National institution publicationsCommon activities within the country such as fuel and electricityThe publication year and the period it applies to should be checked
International organization guidesWhen there is no national value, or for activities in other countriesDifferences in geography and technology should be taken into account
Industry databasesCommon inputs such as materials and productsWhich version is used should be recorded
Supplier-specific data (product carbon footprint)When the supplier has made product-level measurementsThe measurement boundary and method should be asked about; the evidence should be kept

Gases such as methane and nitrous oxide are converted to CO2e with global warming potential coefficients. Because these coefficients can also vary with the version of the published scientific report, the version used in the calculation should be kept together with the factor record.

What information should a factor record contain?

Whether an emission figure is reliable depends less on the figure itself than on the information that produced it being on record. When the question “where did these 3 tonnes come from?” comes later, the answer cannot be given with only the activity data and the factor value. Every factor record should contain the following:

  • Factor value and unit (for example kg CO2e / kWh)
  • Source: which institution, which document or database
  • Publication year and version
  • The period and geography it applies to
  • The gases it covers and the version of the coefficient used in the CO2e conversion
  • Which calculations it is used in and who approved it
  • An evidence file for the source or publication

Five common mistakes when choosing a factor

  1. Not checking the unit. If the factor is given per kWh and you multiply data in MWh, the result is off by a factor of a thousand.
  2. Using last year’s factor without noticing. The file is copied and the factor column is not updated.
  3. Settling for a general factor when a more suitable one exists. For example, using an average factor when product-specific data exists leaves the calculation needlessly uncertain.
  4. Not recording the source. A year later nobody remembers where the figure came from.
  5. Burying the factor in the calculation. If the value is typed by hand into the formula, nobody knows which cell to change during an update.

The quality of the activity data is at least as important as the factor. Measured data taken from an invoice or meter and estimated data entered as “it was about this much” do not carry the same confidence. A good record states whether the data was measured or estimated, so management can see how solid the figure is when reading it.

Where is keeping factors in an Excel sheet enough, and where does it break?

In a small inventory with a single facility, a few activity types and one person maintaining it, keeping the factors on a separate sheet with source and year columns works perfectly well. The break begins when a factor is updated: if the new value is written over the old one, past calculations change on their own; nobody can later see which figure was calculated with which factor. When several people use different values in different files, the same activity ends up with two different results. The solution is to record the factor with versions and to tie each calculation to the version it used; you can do this in Excel too, but it requires discipline.

How does Karbonİz handle the emission factor?

Karbonİz is designed as a data platform that aims to gather carbon data in a single traceable chain of records. At the center of the approach is a calculation ledger that keeps the activity, the factor, the method, the evidence and the approval in the same chain of records. In the data flow of the demo screens, every metric can be traced back to the source record, unit, period, factor version, evidence and approval status. In other words, the aim is that from a result figure you can go back to which activity data was multiplied by which factor version.

To see the approach in which the factor and the activity are linked, together with the scope classification, you can look at our article on Scope 1, 2 and 3 emissions, and for the general flow of the record chain, at the carbon footprint management guide. To examine Karbonİz’s record logic in detail, open the project page.

Frequently asked questions

What is an emission factor?

It is the coefficient that gives how much greenhouse gas one unit of an activity produces, as carbon dioxide equivalent, for example kg CO2e per kilowatt-hour. Activity data is multiplied by this coefficient to convert it into emissions.

Should I calculate the emission factor myself?

In most corporate calculations, no. The factor is taken from the publications of a national institution or an international organization, from industry databases, or from a supplier’s product-specific measurement. You collect the activity data, choose the right factor and record it with its source.

Does the electricity emission factor change every year?

Yes. The factor depends on the country’s electricity generation mix and may be updated when the publishing institution announces new-period data. So you should keep the year and source you used in the record and not silently change old calculations.

Can I keep the emission factor table in Excel?

In a small inventory you can; filling in columns for factor, unit, source, year and period of validity is a sufficient start. When a factor is updated, adding a new row instead of overwriting the old value keeps past calculations traceable.

What does CO2e mean?

It stands for carbon dioxide equivalent. Different gases such as methane and nitrous oxide are expressed in carbon dioxide terms with global warming potential coefficients; this way all gases can be added up in one unit.

FU
Ferhat Uğurlu · YazSis Team

Builds enterprise software, AI and digital transformation products together with the YazSis team.